Shering Command Models 930 and 940

Specifications

Shering Command 930 Digital Weight Indicator    Shering Command 940 Digital Weight Indicator

  Load Cell Interface
Zero Range 0-16mV
Span Range Minimum 3mV @ 3000 div, Maximum 24mV
Resolution 100,000 non-approved
8,388,608 internal counts
Display Updates 10 per second
Stability Span temp coef. <10ppm/ºC>
Zero temp coef. <0.1µV/ºC>
Excitation Voltage 8VDC  12 load cells @ 350 ohms per load cell
Load Cell Sensitivity 0.1mV/V to 3mV/V
Load Cell Cable Length 100m MAX
  Communication
2 Serial Ports Serial 1 provides both RS232 and full duplex RS232/RS485 drivers
Serial 2 provides RS232 only
(An optional RS232 to Current Loop converter is also available which converts the RS232 output to a passive 20mA current loop transmitter)
Data Format 300-19,200 Baud
7-8 data bits
1-2 stop bits
Parity = odd, even, or none
Power
Requirements 86-260VAC 48-62Hz
12/24VDC
Rating 10VA
  Tested to
Mains Interference Immunity to 10 millisecond blackouts
1KV, 50 nanosecond electrical spikes
RFI Immunity The instrument (DWI) is tested over a frequency range of 26-1000MHz at a field strength of 3V/m to EN45501 (Metrological aspects of non-automatic weighing instruments)
ESD (Electrostatic discharge) Immunity to 8KV air discharges
6KV contact discharges
Power Interruption Power fail detect, automatic restart
  Metrological Characteristics
Centre of Zero Indicator illuminated when within ¼ division of gross zero
Over Capacity Indicated on weight display by 0-----kg
Under Zero Display Displays a negative weight
Zero Tracking Compensates for gradual weight changes when the weight display is displaying gross zero
Motion Detection Zero setting, semi-auto tare and printing are inhibited while the weight display is changing
  Mechanical
Weight Display Backlit LCD with 20mm high characters, 6 digit display
Annunciator Chevrons for indicating centre of zero, gross weighing mode, net weighing mode, motion detection
Keyboard Tactile membrane keyboard with audible feedback
Mountings Wall, Desktop, Panel
  Optional
Setpoint Card The Setpoint card provides four opto-isolated open-collector output drive transistors and four opto-isolated inputs
'Combo' Card The 'Combo' card combines the analogue and setpoint functions to provide one opto-isolated input and two opto-isolated open-collector outputs, along with a -10 to +10V or 4-20mA analogue output

Go Back To The Previous Page

Top of page